Real NS0-519 Network Appliance NCIE-SAN Specialist Certification Dumps | DumpsBase
It is your time to take NS0-519 NetApp Certified Implementation Engineer - SAN, ONTAP certification exam now. And the most important is, you do not need to worry about the preparation. DumpsBase has released Real NS0-519 Network Appliance NCIE-SAN Specialist Certification Dumps, with 60 practice exam questions and verified answers, to help you prepare well. Once decide to take DumpsBase NetApp NS0-519 exam dumps and have completed the payment, we will send NS0-519 pdf file and free software both to ensure that you can learn and read NS0-519 exam questions and answers clearly. As recommend, before getting DumpsBase Real NS0-519 Network Appliance NCIE-SAN Specialist Certification Dumps online, you need to read all details about NS0-519 exam first.
Network Appliance NCIE-SAN Specialist, ONTAP Certification Requires To Pass NS0-519 Exam
Are you familiar with NetApp Certified Implementation Engineer—SAN Specialist certification. It proves that you have skills in planning, implementing, integrating, and troubleshooting ONTAP SAN, FC switched fabrics and Ethernet iSCSI/FCoE solutions, and different operating systems (Windows, LINUX, ESX, UNIX) and applications. There are two certifications in NetApp Certified Implementation Engineer—SAN Specialist certification:
NCIE—SAN Specialist, ONTAP logos and certificates will be granted to those individuals who successfully obtain NetApp Certified Data Administrator, ONTAP (NCDA ONTAP) certification, then pass the NetApp Certified Implementation Engineer—SAN (NS0-519) exam.
NCIE—SAN Specialist, E-Series logos and certificates will be granted to those individuals who successfully pass the NetApp Certified Implementation Engineer—SAN, E-Series (NS0-515) exam.
NS0-519 exam is the requirement of Network Appliance NCIE-SAN Specialist, ONTAP Certification. Before taking NS0-519 exam, you are recommended to have six to 12 months of experience in planning, implementing, and validating end-to-end SAN solutions for customers in FC and iSCSI environments. Experience in SAN implementation within virtualized environments and within clustered environments is highly recommended. Also, you are highly recommended to get Real NS0-519 Network Appliance NCIE-SAN Specialist Certification Dumps from DumpsBase as the preparation materials.
NetApp Certified Implementation Engineer—SAN, ONTAP NS0-519 Exam Includes 60 Real Questions
NetApp Certified Implementation Engineer—SAN, ONTAP NS0-519 exam includes 60 real questions, with an allotted time of 1-1/2 hours to complete. In countries where English is not the native language, candidates for whom English is not their first language will be granted a 30-minute extension to the allotted examination completion time. DumpsBase has collected 60 practice exam questions online, we guarantee that NS0-519 exam dumps cover highly, which ensure that you can pass NetApp Certified Implementation Engineer - SAN, ONTAP exam successfully.
More, we check that NS0-519 exam dumps cover each topic of NetApp NCIE-SAN ONTAP NS0-519 exam as listed:
ONTAP® SAN solution assessment
● Identify that all prerequisites for the installation of NetApp® system, hosts, and FCP/FCoE switches are verified.
● Identify a detailed inventory of SAN components
● Describe the solution design and the hardware provisioned to meet customer’s requirements and expectations.
ONTAP SAN planning
● Identify environmental and physical considerations
● Describe storage controller configuration concepts
● Describe switch configuration concepts
● Describe host configuration concepts
● Describe storage space utilization or management concepts
ONTAP SAN implementation and configuration
● Demonstrate knowledge of clustered storage system node configuration tasks
● Demonstrate knowledge of SVM configuration tasks
● Demonstrate knowledge of clustered storage system FCP or NVMe configuration tasks
● Demonstrate knowledge of clustered storage system iSCSI configuration tasks
● Describe how to configure switches
● Describe how to configure host systems
● Demonstrate knowledge of storage space utilization or management concepts
ONTAP SAN implementation testing and troubleshooting
● Demonstrate knowledge of testing tasks
● Demonstrate knowledge of troubleshooting tasks
After you read DumpsBase NS0-519 exam dumps, you can find it is available. Here, we have NS0-519 free demo online for checking.
You are called to help with a new customer's SAN environment that consists of an 8-node AFF A700 cluster, Cisco MDS fabric switches, and Cisco UCS servers.
Which two tools would help you to assess the environment? (Choose two.)
A. Active IQ OneCollect
B. Active IQ Upgrade Advisor
C. NetApp ONTAP Mediator
D. Brocade SAN Health
Answer: AB
Which two SAN components are inventoried by Active IQ OneCollect? (Choose two.)
A. storage controller
B. FC switches
C. power supply
D. fans
Answer: AB
A database owner requests that two additional hosts be added to an application server cluster. This brings the host count for the fabric to 10. The company's internal procedure is to set SAN hosts with a queue depth of 256. The FAS8300 2-node cluster is configured with one HBA per node with one port connected to fabric A and one port connected to fabric B. Users complain about inconsistent performance.
What must the storage administrator do to ensure continuous operation of the hosts in this new configuration?
A. Add two more hosts to the application server cluster.
B. Reduce the number of LIFs per node on the FAS8300 cluster.
C. Create two additional LIFs per node on the FAS8300 cluster.
D. Reduce the queue depth of the hosts such that the total does not exceed 2048.
Answer: D
An administrator enabled the iSCSI protocol on an SVM and created a LUN for a VMware ESXi server.
After the administrator performs a rescan, the LUN is not visible on the host.
Which statement describes how to solve this problem?
A. Create an igroup, add the iSCSI IQN, then map the LUN to the igroup.
B. Enable ALUA support on the VMware host.
C. Perform a takeover/giveback of the controller that is hosting the LUN.
D. Create an igroup, add the WWPN of the host initiator, then map the LUN to the igroup.
Answer: A
You have a 2-node AFF A400 serving FC LUNs. You are asked to make an instant-writable copy of a LUN in a deduplicated volume. The writable copy must not take additional space.
In this scenario, which two ONTAP features would be used? (Choose two.)
A. clone split
B. volume clone
C. LUN move
D. file clone
Answer: BD
You plan to use Foreign LUN Import (FLI) to migrate data from an older storage array to an ONTAP cluster. You have properly cabled the storage array and the NetApp nodes to your dual-fabric SAN.
Which two steps are required for this migration and cutover? (Choose two.)
A. Add NetApp WWN initiator ports to the existing zones.
B. Add NetApp WWN target ports to the existing zones so that your hosts can access both storage arrays.
C. Create two zones that contain the NetApp target ports and the host initiators ports, one for each fabric.
D. Create two zones that contain NetApp initiator ports and the source storage target ports, one for each fabric.
Answer: BC
You are asked to increase the size of your existing 4-node FAS8060 cluster running ONTAP 9.7 software with four additional AFF A700 nodes.
Which tool enables you to confirm that this will be a valid addition?
A. Active IQ OneCollect
B. Hardware Universe (HWU)
C. Active IQ Config Advisor
D. Active IQ
Answer: B
A storage administrator is setting up a Red Hat Enterprise Linux 8.1 system to use NVMe storage in ONTAP 9.7.
In this scenario, which action is required?
A. Load the FC HBA drivers.
B. Set up the Red Hat auto mounter.
C. Load the Ethernet drivers.
D. Set up ALUA.
Answer: A
An administrator suspects abnormal operation and performance-related issues within a particular SAN environment. The administrator wants to further investigate the environment in terms of overall health, best practice recommendations, proactive remediation, and risk assessments, as compared to other SAN deployments.
Which tool should the administrator use to assess this information?
A. Active IQ
B. Active IQ OneCollect
C. Active IQ Config Advisor
D. Interoperability Matrix Tool (IMT)
Answer: C
You are connecting an ISL between two Brocade switches on ports 20 and 21.
Which port-channel type should you configure?
A. U_port
B. FL_port
C. F_port
D. E_port
Answer: D